- Set it &
forget it accuracy
- Longer element
life
- Lower KW
consumption
- No temperature
spikes
- No moving parts
- Large side access
door provides easy access, and inspection
- High efficiency
fluidization manifold means lower maintenance
- Quick change
elements for easy maintenance
- Air expansion
chamber to minimize grain sized sand from
exhausting to dust collection
Heating
Model H-C is
the second style. This unit utilizes a 3-stage
time proportioned contactor control system housed in
a NEMA 12 enclosure. The control system monitors
internal sand temperature while comparing it to the
programmed set point. The elements are wired in
three banks. Voltage is applied to the first bank as
needed. The second and third banks are activated
based on an adjustable delayed time period. We
generally recommend this option only when a facility
suffers from inconsistent power supply that may
adversely affect the SCR unit of the H-Series.
Although less expensive initially, maintenance costs
on this unit tend to be higher due to the increased
constant demand on the first bank of elements. Sand
temperature with the HC-Series are generally
controlled within five degrees of set point.
Temperature
Measurement
A critical part of
heating is measuring the process temperature. In the
H-Series, this is accomplished using a high
tolerance Watlow Heating Control Processor and a
type-J thermocouple. A second thermocouple is used
to monitor sand temperature for over-temperature
control. It is important to note that the tip of
each thermocouple is directly exposed to the sand in
the heater body. This ensures that the measured and
controlled temperatures in the unit are actual, and
not falsely averaged like other units that cover the
thermocouple tip with a secondary iron thermo well
to indicate constant temperature output.
Fluidization
One
of the principles of heating sand is the use of a
fluidized bed to not only convey the sand through
the unit, but also to force each grain of sand into
contact with the heating elements. The H-Series
utilizes as standard a compressed air system to
fluidize the sand. Compressed air is introduced into
the bottom of the heater body. The air is
distributed into the body via an inexpensive canvas
membrane sandwiched between two expanded metal
screens for rigidity. This membrane allows
fluidizing air to enter the body but prevents sand
from falling into the air manifold system.
There are several
benefits to fluidization. The first is sand
temperature consistency. Since each grain is in
constant motion on and around the heating elements,
the sand temperature in the unit will be constant.
This is absolutely critical for consistent
temperature sand out of the unit.
A second advantage to
fluidization is that fines can be removed from the
sand just prior to it entering the sand mixer or
mixing system. A standard component of the H-Series
is a heavy-duty steel fabricated expansion chamber
that allows grain size material to drop back into
the unit from the exhaust air while allowing the
fines to be pulled to the baghouse. This helps to
reduce fines generated by sand transport and allows
lower resin levels to be used.
Compressed Air
Manifold
As
a part of the standard unit, a full air manifold
system is provided. This manifold includes a high
efficiency bowl filter, Laman Brand dual stage
cartridge filtering device, heavy-duty fluidization
solenoid, air pressure regulator, and air pressure
switch. The high efficiency air filtration system
eliminates the saturation problems normally
associated with fluidized bed membranes. The bowl
filter and Laman Brand filter work together to
eliminate 98.6% of water in the feeding air line
reducing canvas replacement. The pressure regulator
ensures that fluidized bed pressure is maintained
constant. The air pressure switch is used as a
safety device to shut down the heating circuit if
there is insufficient air pressure to fluidize the
sand, protecting the heating circuitry and elements.
Inlet Control
Valve
An
important function in fluidized bed applications is
maintaining a constant fluid bed depth. This aides
not only in heating, but also fluidizing. One
component required to accomplish this is an inlet
control valve. This valve is used to shut off the
supply of sand to the heater when the mixer is not
calling for sand. The goal of this valve is to
prevent packing the heater body. This valve
eliminates problems with other systems that do not
provide the valve as standard. These problems are
inconsistent sand temperature, inconsistent
fluidization, inconsistent sand flow, etc.
This valve also
allows the continuation of fluidization after a
heating cycle. This is important since the heating
elements of the unit will have residual heat. If the
sand is not fluidized after the cycle, the resonant
heat in the elements will build up in the sand
immediately around the elements. This not only
causes inconsistent sand temperature, but also
shortens element life. By shutting off the sand
going into the unit, sand exiting the unit will also
stop (a principle of the fluidized bed). The
fluidizing air can continue
to run without packing the heater body or
overflowing the mixer inlet hopper or receiver.
Summer /
Maintenance By-Pass Valve
The H-Series heaters
come standard with a manually actuated butterfly
valve that is used as a summer or maintenance
bypass. Once the by-pass valve is opened there is no
need for the fluidizing air to pass sand through the
unit to convey sand. Energy savings are naturally
assumed in the summer months and preventative
maintenance functions can be performed without
stopping production. A switch on the door of the
primary electrical enclosure switches the unit from
heat to by-pass mode electrically.
Electrical
Configuration
All
electrical controls are housed in NEMA 12 dust tight
enclosures. The primary electrical controls mount at
floor level in most applications while the heater
body is suspended above the mixer. The heater body
has three primary electrical connection areas: the
air valve enclosure, the power distribution
enclosure, and the body top enclosure.
- The
air valve enclosure houses the air solenoid valve
used to trigger the air actuated inlet butterfly
valve. It also contains the thermocouple termination
points.
- The power distribution enclosure
houses the three phase power connections going to
the heating bundle.
- The body top enclosure
houses the tips of the heating elements as well as
the interconnecting wiring of those elements.
Mechanical
Configuration
There
are a few significant advantages of the H-Series
over others. One is that the heating bundle used is
designed into, installed, and wired as an integral
part of the unit. Palmer does not use a purchased,
drop-in industrial heating bundle like others. This
allows for a single element to be easily replaced
rather than waiting for the majority of the bundle
to fail and replacing the entire heating bundle.
The H-Series also
offers two ways to access the elements, either from
the bottom (common) or the side. This makes element
replacement and heater inspection much easier.
The heavy duty steel
fabrication offers years of service resisting the
abrasive action of the sand. The unit can be
suspended by hanger bolts or directly bolted to top
mounting rails provided to the bottom of structural
I-beam or channel.
The large side access
panel provides easy, quick access to the elements
and fluidized bed membrane for inspection and
maintenance.
Please Note:
When any machine containing a sand control device
(valve or slidegate) is installed, it is always a
good idea to install a manual service valve in the
supply pipe above the device. This allows
maintenance service and inspections to be performed
on the control device without requiring the
silo/hopper to be empty.
Available Models
| |
H100 |
H300 |
H500 |
H1000 |
H1500 |
H2000 |
| KW
Rating |
22.5 |
45 |
90 |
150 |
225 |
300 |
| Temperature
Rise (Based on Silica Sand) |
45°F
at 100 lbs/min |
35°F
at 300 lbs/min |
35°F
at 500 lbs/min |
35°F
at 1000 lbs/min |
35°F
at 1500 lbs/min |
35°F
at 2000 lbs/min |
| Number
of Heating Elements |
18 |
18 |
36 |
60 |
90 |
120 |
| Actual
Max System Amps |
27 |
54.1 |
108.3 |
108.4 |
270.6 |
361.3 |
| Electrical
Service Required |
480
V / 3-PH / 30A |
480
V / 3-PH / 60A |
480
V / 3-PH / 125A |
480
V / 3-PH / 200A |
480
V / 3-PH / 300A |
480
V / 3-PH / 400A |
| Compressed
Air Requirement |
20
CFM @ 90 PSI |
20-30
CFM @ 90 PSI |
75-100
CFM @ 90 PSI |
75-100
CFM @ 90 PSI |
100-120
CFM @ 90 PSI |
100-120
CFM @ 90 PSI |
| Exhaust
Air Requirement |
50
SCFM |
60
SCFM |
180
SCFM |
290
SCFM |
600
SCFM |
800
SCFM |
| Over-Temp
Shut Down Method |
Contactor |
Contactor |
Shunt
Trip |
Shunt
Trip |
Shunt
Trip |
Shunt
Trip |
Available Options
Regenerative
Blower System - Used to provide Fluidizing Air
to the Heater instead of the standard compressed air
fluidizing manifold. Includes motor starter,
integral wiring, inlet air filter and silencer. View
Photo
Dual Fluidization
Systems - This option includes both the standard
fluidizing manifold as well as the regenerative
blower system. This option also includes a switch in
the primary electrical panel to switch from the
blower to compressed air.
Custom Voltages
- Although the H-Series is offered standard as a 480
Volt - 3 Phase unit, it can also be supplied in
240V, 380V, and 575V formats.
Discrete Outputs
- For sand preparation systems that are integrated
into a common PLC for overall control, the H-Series
can be outfitted to include discrete sensors for
primary operational functions such as inlet valve
position, fluidizing air presence, heating unit
engagement, etc.
|